5-1-4-snyatie-i-ustanovka-rasshiritelnogo-bachka.html
5.1.4. Removal and installation of a broad tankModels with engines, except M57 and M67
|
- Lower cooling liquid only to a point below level of a broad tank.
|
- Separate the socket of electroconducting of the sensor of level of OZh (A), weaken a collar (B) and disconnect a hose from a broad tank.
|
- Uncover a broad tank and completely turn out the screw for pumping of system of cooling.
|
- Liberate from clamps an overlay of fastening of a broad tank.
|
|
- Delay a broad tank back and remove a ventilation hose.
|
|
- Liberate a broad tank from the bottom fixing pads and remove movement up.
|
|
At installation holders should enter into grooves on a fan casing. |
- Installation is made upside-down. In summary pump over system of cooling and check it on tightness.
|
|
Models with the M57 engine
|
- Close the generator to prevent hit on it impellent oil, fuel or OZh.
- Lower cooling liquid (see. The section Replacement of cooling liquid of Head of Control and routine maintenance of the car).
|
- Disconnect perepuskny a hose (1). Extend a cap movement up and weaken a collar (2) fastenings of a hose for air removal. Weaken a collar (3) and disconnect a hose.
|
- Wring out a clamp (4) and remove a broad tank (5) movement up. Separate the socket of electroconducting of the sensor of level of OZh on the bottom party of a broad tank.
|
At installation replace a collar (2) and to rearrange the sensor on a new broad tank. |
|
|
Models with the M67 engine
|
- Lower OZh (see. The section Replacement of cooling liquid of Head of Control and routine maintenance of the car).
|
- Take rivets (1), uncover (2), compress fixing pads of an arm (3) and remove it movement up.
|
|
- Lift a casing (1) fan by means of a screw-driver (2) over the screw (3) pumpings of system of cooling. Remove a broad tank (4) movement back.
|
|
- Cut a collar (1) and disconnect a hose (2) ventilations.
|
|
At installation use a new collar (1). |
|
- Weaken a collar (1) fastening of a water hose (2) and disconnect it from a broad tank (4). Separate the socket (3) sensors of level of OZh.
|
- Installation is made upside-down. If necessary rearrange the sensor of level of OZh on a new broad tank.
|
|
|
|